Chapter 7 Menu Operations — Menu list
[BATTERY/P2CARD]
Item Description of settings Remark
[BATTERY SELECT] Selects the battery to use. fWhen the battery charge level percentage
cannot be detected, it will follow the setting value
of [TYPE A] even if it is set to [BATT STAT] or
[ENDURA STAT]. Make sure that the [TYPE A]
setting values [FULL] (fully charged), [NEAR END]
(near end), or [END] (end) is appropriate for the
battery being used.
[HYTRON140] Detects the battery charge level according to the selected
battery when the Anton/Bauer HYTRON140 or DIONIC90, the
IDX ENDURA10 (E-10), and the PAG PAG L96e are selected.
[DIONIC90]
[ENDURA10]
[PAG L96e]
[TYPE A] Select any item when a battery other than [HYTRON140],
[DIONIC90], [ENDURA10], or [PAG L96e] is used. At this
time, set [FULL] (full voltage), [NEAR END] (near end warning
voltage), and [END] (end voltage) in the main menu → [I/F
SETUP] → [BATTERY SETTING] (page 163) according to the
battery in use.
[TYPE B]
[TYPE C]
[BATT STAT] When using a battery whose charge level is detected as a
percentage value, near end and end operation is conducted
according to the percentage value of the charge level if
[BATT STAT] is selected. Set the percentage value of [BATT
STAT NEAR END] (near end) and [BATT STAT END] (end)
in the main menu → [I/F SETUP] → [BATTERY SETTING]
(page 163) according to the battery in use.
[ENDURA
STAT]
Select when IDX ENDURA battery is used to operate at near
end and end according to the percentage value of the charge
level information. Set the percentage value of [ENDURA STAT
NEAR END] (near end) and [ENDURA STAT END] (end)
in the main menu → [I/F SETUP] → [BATTERY SETTING]
(page 163) according to the battery in use.
[EXT DC IN SELECT]
Sets the type of charge level to connect a battery to the <DC IN> terminal. Also
detects a charge level that corresponds to the selected type.
Information about selecting a battery type is the same as [BATTERY SELECT].
Displays the analog voltage on the viewnder screen.
[DC PWR SUPPLY], [HYTRON140], [DIONIC90], [ENDURA10], [PAG L96e],
[TYPE A], [TYPE B], [TYPE C]
[BATT NEAR END
ALARM]
Selects whether to play the warning sound at battery near end.
[ON], [OFF]
[BATT NEAR END
CANCEL]
If set to [ON], the warning sound and warning display output can be canceled
when the <MARKER SEL>/<MODE CHECK/MENU CANCEL> switch is pushed
towards the <MCK/MCL> side at battery near end.
[ON], [OFF]
[BATT END ALARM]
Sets whether to output the warning sound at battery near end.
[ON], [OFF]
[BATT REMAIN FULL] Sets the content of the battery remaining charge bar of the display window when a
battery with charge level display function is used.
[70%] Fully displays at 70%.
[100%] Fully displays at 100%.
[CARD NEAR END
ALARM]
Sets whether to output the warning sound at P2 card near end.
[ON], [OFF]
[CARD NEAR END
TIME]
Sets remaining time to emit the P2 card near end warning.
[2min], [3min]
[CARD END ALARM]
Sets whether to output the warning sound at P2 card end.
[ON], [OFF]
[CARD REMAIN/Seg]
Sets the time of one segment (r) for the P2 card remaining capacity bar in the
display window.
[3min/Seg] One segment is three minutes
[5min/Seg] One segment is ve minutes
are factory settings.
[BATTERY SETTING]
Item Description of settings Remark
[BATTERY MODE] Selects whether to set the near end voltage of a battery.
[AUTO] Automatically set.
[MANUAL] Manually set.
[HYTRON140 NEAR
END]
Selects the near end voltage in steps of 0.1 V when the main menu → [I/F
SETUP] → [BATTERY/P2CARD] → [BATTERY SELECT] is set to [HYTRON140].
[12.0V]…[13.1V]…[15.0V]
[DIONIC 90 NEAR
END]
Selects the near end voltage in steps of 0.1 V when the main menu → [I/F
SETUP] → [BATTERY/P2CARD] → [BATTERY SELECT] is set to [DIONIC90].
[12.0V]…[13.7V]…[15.0V]
are factory settings.