0

Out of 0 Ratings

Owner's of the Kramer Electronics TV Cables Kramer Electronics TV Cables gave it a score of 0 out of 5. Here's how the scores stacked up:
  • Reliability

    0 out of 5
  • Durability

    0 out of 5
  • Maintenance

    0 out of 5
  • Performance

    0 out of 5
  • Ease of Use

    0 out of 5
of 56
 
KRAMER: SIMPLE CREATIVE TECHNOLOGY
Communication Parameters
36
11 Communication Parameters
Table 5 lists the communication parameters as used in Kramer Electronics
products.
Table 5: Communication Parameters
EDID
EDID data is passed between Output 1 and Input 1
RS-232
Protocol 2000 Protocol 3000 (Default)
Baud Rate: 9600 Baud Rate: 115,200
Data Bits: 8 Data Bits: 8
Stop Bits: 1 Stop Bits: 1
Parity: None Parity: None
Command Format: HEX Command Format: ASCII
Example (Output 1 to Input 1): 0x01, 0x81, 0x81, 0x81 Example (Output 1 to Input 1): #AV 1>1<CR>
Switching Protocol
P2000 -> P3000 P3000 -> P2000
Command: 0x38, 0x80, 0x83, 0x81 Command: #P2000<CR>
Front Panel: Press and hold Output 1 and
Output 3 simultaneously
Front Panel: Press and hold Output 1 and
Output 2 simultaneously
Ethernet
Default Settings Reset Settings
IP Address: 192.168.1.39 Power cycle the unit while holding in the Factory Reset button, located on
the rear panel of the unit.
TCP Port #: 5000
UDP Port #: 50000
12 Table of ASCII Codes for Serial Communication (Protocol
3000)
Table 6 and Table 7 list the ASCII values to switch an input to an output for a
single VP-4x8AK machine. For more detailed information, see Protocol 3000
(Section
14.2).
Table 6: VP-4x8AK Video Signal Codes for Protocol 3000
OUT 1
OUT 2
OUT 3
OUT 4
OUT 5
OUT 6
OUT 7
OUT 8
IN 1
#V 1>1 CR #V 1>2 CR #V 1>3 CR #V 1>4 CR #V 1>5 CR #V 1>6 CR #V 1>7 CR #V 1>8 CR
IN 2
#V 2>1 CR #V 2>2 CR #V 2>3 CR #V 2>4 CR #V 2>5 CR #V 2>6 CR #V 2>7 CR #V 2>8 CR
IN 3
#V 3>1 CR #V 3>2 CR #V 3>3 CR #V 3>4 CR #V 3>5 CR #V 3>6 CR #V 3>7 CR #V 3>8 CR
IN 4
#V 4>1 CR #V 4>2 CR #V 4>3 CR #V 4>4 CR #V 4>5 CR #V 4>6 CR #V 4>7 CR #V 4>8 CR