Error/Warning Indications
61
Appendices
The camcorder informs you of situations where warning, caution, or an operation check is required,
through messages on the LCD/viewfinder screen, the recording lamp, and a buzzer.
The buzzer is output to the headphones connected via the headphone connector.
The camcorder stops operation after the following indications.
When one of the following indications is generated, follow the message to resolve the problem.
Error/Warning Indications
Error indications
Error indication on
LCD/viewfinder
Buzzer Recording
lamp
Cause and measures
C:04:ss The battery pack is not an “InfoLITHIUM” battery pack. Use
an “InfoLITHIUM” battery pack (page 54).
C:06:ss The battery pack temperature is high. Change the battery
pack or place it in a cool place.
C:32:ss Remove the power source. Reconnect it and operate your
camcorder again.
E:20:ss/E:40:ss/
E:41:ss/E:50:ss/
E:51:ss/E:61:ss/
E:62:ss/E:92:ss/
E:94:ss/E:95:ss
Perform the following steps.
1 Check the list, and inspect your camcorder.
2 Disconnect the power source, attach the power source again
after about 1 minute, and turn the camcorder on.
3 Contact your Sony dealer or local authorized Sony service
facility.
Warning indications
Warning indication
on LCD/viewfinder
Buzzer Recording
lamp
Cause and measures
Media Near Full Intermittent Flashing Free space on the XQD memory card has become
insufficient.
Replace it with another at the earliest opportunity.
Media Full Continuous Rapidly
flashing
No space is left on the XQD memory card. Recording, clip
copying and clip division cannot be performed.
Replace it with another.
Battery Near End Intermittent Flashing The battery power will be discharged soon.
Charge the battery pack at the earliest opportunity.
Battery End Continuous Rapidly
flashing
The battery pack is discharged. Recording cannot be
performed.
Stop operation and change the battery pack.
Battery Temperature
High
Turn Power Off
The temperature of the battery pack has risen above a safe
operation limit.
The camcorder turns off automatically.
Temperature High Intermittent Flashing The internal temperature has risen above a safe operation
limit.
Suspend operation, turn off the power, and wait until the
temperature falls.
Battery Error
Please Change Battery
An error was detected with the battery pack.
Replace the battery pack with a normal one.